
6
Main Power Connection
Caution!
1. Do not connect fixture to a dimmer system.
2. This unit must be earthed. (electronically grounded)
3. Replace fuse only with the specified type and rating.
The occupation of the connection-cable is as follows:
Cable (USA) Cable (EU) Pin International
Brown Brown
Blue
Yellow / Green
Blue
Yellow/Green
Live
Neutral
Pin
L
N
1
2
3
1
3
2
DMX-512 Connection
110V 50/60hz Connection
The fixture is equipped with 3 pin XLR Sockets for DMX input and output. The sockets are wired in parallel. Only use a shielded
twisted pair cable designed for RS-485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or
the fixture with another.
DMX—input
DMX—output
1. Shield
2. Signal (-)
3. Signal (+)
Caution!
At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120
Ohm resistor between the (-) and the (+) signal into a 3 pin XLR plug and plug it in to the
last fixture on the signal run. Pre-manufactured terminator plugs are available for
purchase from your Mega-Lite dealer (HOS-DMXT).
Kommentare zu diesen Handbüchern